coolingtips

coolingtips

@coolingtips

HVACR Tech Nairobi | Cold rooms • Chillers • Commercial refrigeration 📞 +254745261470 |

coolingtips est un créateur TikTok, avec 10.7K abonnés et 55.5K j'aime. Ses vidéos cumulent en moyenne 11.5K vues, pour un taux d'engagement de 4.4%. Hashtags les plus utilisés: #hvacr, #refrigeration et #hvactechnician.

10.7K
Abonnés
10K
Abonnements
55.5K
J'aime
11.5K
Vues moyennes
Engagement: 4.4% Kenya 🗣️ anglais
10.7K
Abonnés
55.5K
Total de j'aime
11.5K
Vues moyennes
118
Vidéos
10K
Abonnements
0
Favoris
4.4%
Engagement

Croissance & prévisions

Dernière mise à jourPrévision 7 joursPrévision 30 jours
Abonnés10.7K🔒 Pro🔒 Pro
Total de j'aime55.5K🔒 Pro🔒 Pro
Vidéos118🔒 Pro🔒 Pro
Vues moyennes11.5K🔒 Pro🔒 Pro

Débloquez le rapport complet

E-mail de contact, historique de croissance et prévisions, et archive complète des vidéos sont inclus dans Pro.

Voir le rapport complet →

Pro est gratuit pendant la bêta : essai sans carte bancaire.

Revenus estimés

Tarif estimé par publication sponsorisée: de $50 à $250, sur la base d'environ 5 à 25 $ pour 1 000 abonnés. C'est une estimation à partir de la taille de l'audience, pas un revenu déclaré.

Dernière mise à jour:

Profil TikTok

Vidéos récentes

Dernière vidéo: 2026-10-14

AC instalation
▶
▶ 1.9K ❤ 0 💬 0

AC instalation

❄️🔧 WHEN REPAIR AFTER REPAIR IS NO LONGER THE SOLUTION! 🧊 This cold room had been running on a Bitzer Mark 3 compressor, but the system had reached a point where a complete overhaul was necessary. The compressor was leaking and had suffered mechanical damage. It was making abnormal noises while running — clear signs that something was seriously wrong. 🔊⚠️ The evaporator coil had also gone for a very long time without proper servicing and had undergone multiple repairs over the years. At that point, continuing with patchwork repairs was no longer the best solution. So we decided to do it properly. 👷🏾‍♂️🔧 🔩 We replaced: ✅ Bitzer condensing unit ✅ Evaporator coil ✅ Control panel ✅ Refrigeration piping ✅ Refrigeration connections and components Then we carried out pressure testing, leak testing, proper vacuuming, refrigerant charging and commissioning to make sure the system was operating correctly. ❄️📊 💡 Lesson: Sometimes continuous repairs only keep an old system alive for a little longer. When major components are damaged, heavily repaired or neglected, a proper system overhaul can be the better investment. Don't just repair the symptom. Find the cause. Fix it properly. 💯 📞 Need cold room installation, servicing or repair? 📲 +254 745 261 470 📲 +254 702 163 277 #ColdRoom #Bitzer #Refrigeration #HVACR #ColdRoomRepair
▶
▶ 1.4K ❤ 0 💬 0

❄️🔧 WHEN REPAIR AFTER REPAIR IS NO LONGER THE SOLUTION! 🧊 This cold room had been running on a Bitzer Mark 3 compressor, but the system had reached a point where a complete overhaul was necessary. The compressor was leaking and had suffered mechanical damage. It was making abnormal noises while running — clear signs that something was seriously wrong. 🔊⚠️ The evaporator coil had also gone for a very long time without proper servicing and had undergone multiple repairs over the years. At that point, continuing with patchwork repairs was no longer the best solution. So we decided to do it properly. 👷🏾‍♂️🔧 🔩 We replaced: ✅ Bitzer condensing unit ✅ Evaporator coil ✅ Control panel ✅ Refrigeration piping ✅ Refrigeration connections and components Then we carried out pressure testing, leak testing, proper vacuuming, refrigerant charging and commissioning to make sure the system was operating correctly. ❄️📊 💡 Lesson: Sometimes continuous repairs only keep an old system alive for a little longer. When major components are damaged, heavily repaired or neglected, a proper system overhaul can be the better investment. Don't just repair the symptom. Find the cause. Fix it properly. 💯 📞 Need cold room installation, servicing or repair? 📲 +254 745 261 470 📲 +254 702 163 277 #ColdRoom #Bitzer #Refrigeration #HVACR #ColdRoomRepair

COMPRESSOR SWAP COMPLETE! Prasad GWK WECO 31L commercial Water Chiller 💨 34 kW / 9.7 TR | R134a | 7kg Recover → Replace → Nitrogen brazing → Leak test → Deep vacuum → Recharge → Startup ✅ Proper procedure = reliable cooling! 💪🏾❄️ 📞 HVACR Services: +254 745 261 470 / +254 702 163 277 📧 coolingtips@gmail.com 🎥 Follow CoolingTips for the full video! #HVACR #ChillerRepair #CompressorReplacement #R134a #CoolingTips
▶
▶ 1.7K ❤ 0 💬 0

COMPRESSOR SWAP COMPLETE! Prasad GWK WECO 31L commercial Water Chiller 💨 34 kW / 9.7 TR | R134a | 7kg Recover → Replace → Nitrogen brazing → Leak test → Deep vacuum → Recharge → Startup ✅ Proper procedure = reliable cooling! 💪🏾❄️ 📞 HVACR Services: +254 745 261 470 / +254 702 163 277 📧 coolingtips@gmail.com 🎥 Follow CoolingTips for the full video! #HVACR #ChillerRepair #CompressorReplacement #R134a #CoolingTips