95.2K
Followers
737.6K
Total likes
2.1K
Avg views
1.3K
Videos
4K
Following
0
Favorited
0.6%
Engagement

Growth & Forecast

Last updated7-day forecast30-day forecast
Followers95.2K▲ 🔒 Pro🔒 Pro
Total likes737.6K▲ 🔒 Pro🔒 Pro
Videos1.3K🔒 Pro🔒 Pro
Avg views2.1K▲ 🔒 Pro🔒 Pro

Unlock the full report

Contact email, growth history and forecasts, and the full video archive are part of Pro.

View full report →

Pro is free during the beta: start a trial, no credit card required.

Estimated earnings

Estimated rate per sponsored post: $475 to $2.4K, based on roughly $5 to $25 per 1,000 followers. This is an estimate from audience size, not reported income.

Last updated:

TikTok profile

Recent videos

Latest video: 2026-11-01

#stitch with @🇳🇴 Muhammad Noman that was my 1st lesson that download with Allen-Bradley is not the same compared to Siemens. it was a million dollar lesson and 6 hours of down time. luckily the senior had a backup copy saved. #allenbradley #controlsengineering #IndustrialAutomation #PLCprogramming
▶
▶ 412 ❤ 0 💬 0

#stitch with @ Muhammad Noman that was my 1st lesson that download with Allen-Bradley is not the same compared to Siemens. it was a million dollar lesson and 6 hours of down time. luckily the senior had a backup copy saved. #allenbradley #controlsengineering #IndustrialAutomation #PLCprogramming

how to check a blown fuse with a multimeter without pulling it. control transformer: 480 V primary through FU1 and FU2, 120 V secondary out of X1 through FU3. no control power. meter on V AC, across FU1: 0 V. across FU2: 0 V. X1 to X2 at the transformer: 121 V, so the transformer is fine. across FU3: 121 V. zero volts across a fuse means it's good. full voltage across it means it's open, because the load is completing the circuit. FU3's blown. do you test fuses live or pull them and ohm them? #blownfuse #fuse #multimeter #controltransformer #electrician #industrialelectrician #maintenancetechnician #troubleshooting #controlstech #electricalengineering #motorcontrol #automation
▶
▶ 2K ❤ 0 💬 0

how to check a blown fuse with a multimeter without pulling it. control transformer: 480 V primary through FU1 and FU2, 120 V secondary out of X1 through FU3. no control power. meter on V AC, across FU1: 0 V. across FU2: 0 V. X1 to X2 at the transformer: 121 V, so the transformer is fine. across FU3: 121 V. zero volts across a fuse means it's good. full voltage across it means it's open, because the load is completing the circuit. FU3's blown. do you test fuses live or pull them and ohm them? #blownfuse #fuse #multimeter #controltransformer #electrician #industrialelectrician #maintenancetechnician #troubleshooting #controlstech #electricalengineering #motorcontrol #automation

Don’t get me wrong I love a clean panel but I’m so used to the messy ones I’m toxic and love the mess. It gives me a rush I can’t explain 😂😂 #mechatronics #industrialautomation #electrical #electrician #wiring
▶
▶ 566 ❤ 0 💬 0

Don’t get me wrong I love a clean panel but I’m so used to the messy ones I’m toxic and love the mess. It gives me a rush I can’t explain 😂😂 #mechatronics #industrialautomation #electrical #electrician #wiring

Frequently asked questions

How many followers does Markus864 have?

Markus864 (@markus864) has 95.2K TikTok followers as of 2026-11-01.

Similar creators

Top TikTok Creators in the United States

View all →
charli d’amelio @charlidamelio
#2

orca enthusiast meg thee stallion fan i post on youtube on saturdays (for the most part)

Followers
160.3M
Likes
12.4B
Views
3.9M
Engage
2.3%
TikTok @tiktok
#4

Your next discovery is waiting on TikTok.

Followers
96.5M
Likes
465.7M
Views
559.7K
Engage
0.3%